Structure
Application range
It is the most basic form of a silicone rubber wire, and is most often used in itself, and is also used as an internal core wire of a composite structure.
It is mainly used for internal wiring of devices in high temperatures, signage electrical wiring, and inverter internal wiring. In addition, lighting equipment and heating equipment are widely used.
Features
ㆍ Physical-chemical
- Allowable temperature –60℃ to +200℃
- Excellent heat resistance, cold resistance, flexibility, and electrical insulation
- Able to be repurposed for various purposes such as high tear strength, high voltage, etc.
- Use for environments that require flexibility compared to SRG
ㆍ Electrical features
- Rated voltage : 300V / 600V or 1,000V(Depends on UL Style)
- Test voltage : 2,000V/min(Depends on UL Style)
Ensuring quality related to environmentally hazardous substances
This product does not contain lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (Cr6+), PPBs, PBDEs, and four types of phthalates, which are regulated as environmentally hazardous substances.
General specifications
Conductor
| Insulation
thickness (㎜) | External diameter
| Remark
|
Cross-sectional area (SQ) | Conductor composition(本/㎜) | External diameter (㎜) | Standard value (㎜) | Allowable tolerance (±㎜) |
0.50
| 20 / 0.18
| 0.93
| 1.00
| 3.0 | 0.20
|
|
0.50
| 20 / 0.18
| 0.93
| 1.50
| 4.0
| 0.20
|
|
0.50
| 20 / 0.18
| 0.93
| 2.00
| 5.0
| 0.20
|
|
0.75
| 30 / 0.18
| 1.14
| 0.90
| 3.0
| 0.20
|
|
0.75
| 30 / 0.18
| 1.14
| 1.40
| 4.0
| 0.20
|
|
0.75
| 30 / 0.18
| 1.14
| 1.90
| 5.0
| 0.20
|
|
1.25
| 50 / 0.18
| 1.47
| 0.75
| 3.0
| 0.20
|
|
1.25
| 50 / 0.18
| 1.47
| 1.25
| 4.0
| 0.20
|
|
1.25
| 50 / 0.18
| 1.47
| 1.75
| 5.0
| 0.20
|
|
0.37
| 7 / 0.26
| 0.79
| 1.60
| 4.0
| 0.20
|
|
0.64
| 12 / 0.26
| 1.04 | 1.50
| 4.0
| 0.20
|
|
0.80
| 7 / 0.40
| 1.22
| 1.90
| 5.0
| 0.20
|
|
14.0
| 7 / 12 / 0.45
| 5.40
| 1.40
| 8.2 | 0.50
|
|
22.0
| 7 / 19 / 0.45
| 6.79
| 1.40
| 9.6 | 0.50
|
|
38.0 | 7 / 33 / 0.45
| 8.95
| 1.40
| 11.8
| 0.50
|
|
* Other specifications and colors are order specifications.
UL certification status
ㆍUL certification in this product is included in UL File E120271 and is shown in the table below.
UL Style
| Rated
| AWG NO.
| Certification acquisition date
|
3132 | 150℃ 300V
| 30 - 4/0
| 1989. 07. 28
|
3133
| 150℃ 600V
| 30 - 4/0
| 1993. 05. 27 |
3135 | 200℃ 600V
| 26 - 12
| 1989. 07. 28
|
3367
| 200℃ 300V
| 26 - 10
| 1989. 07. 28
|
3512 | 200℃ 600V
| 0.3 ~ 250SQ
| 2001. 05. 21
|
*Click to check the standard table.
Structure
Application range
It is the most basic form of a silicone rubber wire, and is most often used in itself, and is also used as an internal core wire of a composite structure.
It is mainly used for internal wiring of devices in high temperatures, signage electrical wiring, and inverter internal wiring. In addition, lighting equipment and heating equipment are widely used.
Features
ㆍ Physical-chemical
- Allowable temperature –60℃ to +200℃
- Excellent heat resistance, cold resistance, flexibility, and electrical insulation
- Able to be repurposed for various purposes such as high tear strength, high voltage, etc.
- Use for environments that require flexibility compared to SRG
ㆍ Electrical features
- Rated voltage : 300V / 600V or 1,000V(Depends on UL Style)
- Test voltage : 2,000V/min(Depends on UL Style)
Ensuring quality related to environmentally hazardous substances
This product does not contain lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (Cr6+), PPBs, PBDEs, and four types of phthalates, which are regulated as environmentally hazardous substances.
General specifications
Insulation thickness
(㎜)
Cross-sectional area
(SQ)
Conductor composition(本/㎜)
External diameter
(㎜)
(㎜)
Allowable tolerance
(±㎜)
* Other specifications and colors are order specifications.
UL certification status
ㆍUL certification in this product is included in UL File E120271 and is shown in the table below.