Structure
Application range
ㆍParallel structure provides constant first designed unit power regardless of length or ambient temperature
ㆍIndustrial pipeline system, prevention of freezing of tanks
ㆍPreventing freezing of household water pipes or other pipes
ㆍPreventing temperature changes in pipes such as high pressure stream cleaning
Technical specifications
ㆍRange of operating temperature : -60℃ ~200℃
ㆍApplied voltage : 110V or 220V (The applied voltage can be designed to change upon customer request
ㆍDesign capacity : 30W/m (10W/m ~50W/m)
ㆍBuswire : 1.3sqmm (10~40W/m) / 2.5sqmm (50W/m)
ㆍSurface temperature by output level (Based on room temperature 20℃)
Unit output | 10W/m | 20W/m | 30W/m | 40W/m | 50W/m |
Surface temperature | 40℃ | 60℃ | 70℃ | 80℃ | 100℃ |
* Since it is not a self-control method, a separate controller sensor device is required because the temperature rise may vary depending on the insulation treatment.
ㆍMaximum usage length (based on 90% output)
Unit output | 10W/m | 20W/m | 30W/m | 40W/m | 50W/m |
Maximum usage length | 83m | 58m | 48m | 41M | 37M |
* The above values are design reference values based on the voltage used (220V) and bus wire (1.0sqmm) and are not absolute values.
Product model classification
Model | Structure | Size | Design |
YKH-101 | Basic type | 5.65/8.90 | |
YKH-102 | Basic type + Exterior braiding | 6.15/9.40 | |
YKH-103 | Basic type + Shielding braiding + External sheath (Silicone) | 7.90/11.50 | |
YKH-104 | Basic type + Shielding braiding + External sheath (Fluororesin) | 6.20/10.40 | |
YKH-105 | YKH-103 + Glass fiber braiding/varnish coating | 8.50/12.10 | |
Structure
Application range
ㆍParallel structure provides constant first designed unit power regardless of length or ambient temperature
ㆍIndustrial pipeline system, prevention of freezing of tanks
ㆍPreventing freezing of household water pipes or other pipes
ㆍPreventing temperature changes in pipes such as high pressure stream cleaning
Technical specifications
ㆍRange of operating temperature : -60℃ ~200℃
ㆍApplied voltage : 110V or 220V (The applied voltage can be designed to change upon customer request
ㆍDesign capacity : 30W/m (10W/m ~50W/m)
ㆍBuswire : 1.3sqmm (10~40W/m) / 2.5sqmm (50W/m)
ㆍSurface temperature by output level (Based on room temperature 20℃)
* Since it is not a self-control method, a separate controller sensor device is required because the temperature rise may vary depending on the insulation treatment.
ㆍMaximum usage length (based on 90% output)
* The above values are design reference values based on the voltage used (220V) and bus wire (1.0sqmm) and are not absolute values.